Fluorescent labelsBiotin and linker recordsStable-isotope documentation
Home / Reading a Modified Peptide COA, HPLC and MS Reports

Reading a Modified Peptide COA, HPLC and MS Reports

Check which question each release document answers for the exact modified material supplied.

Which document identifies the delivered lot?

Start with the lot on the vial and compare it with the certificate, chromatogram and mass report. Record the sample identifier and analytical date shown on the supporting files. A generic example may be useful for agreeing the expected report layout, while a receiving decision requires the actual material to be identifiable. Ask whether the reported material name includes the chemical label or points to a corresponding approved variant record.

Bachem · Quality control of amino acids and peptides

Red-capped sample vials sit beneath the head of an HPLC autosampler.
Capped HPLC sample vialsVial positions provide a physical point of reference when matching a sample identifier to an analytical record.
Image creditsMartin Schaier · Image source · CC BY 4.0 · Converted to WebP.
A workbench holds sample racks, capped vials and preparation equipment.
Laboratory sample stationSeparate racks illustrate why the receiving list needs a unique identifier for each group of containers.
Image creditsGold Standard Analytics LLC · Image source · CC BY-SA 4.0 · Converted to WebP.

What does each analytical result address?

Chromatographic purity, an identity assessment and a peptide content determination describe different attributes. Check how each value is named, what unit or basis is used, and whether the laboratory provides an interpretation for the proposed modified material. A mass report may support overall identity while leaving an attachment-position question open. Agree the reports needed for the purchasing decision and keep additional services listed separately on the quotation.

Bachem · Custom peptide modification and analytical services

What should trigger a document query?

Consider a certificate carrying a labelled product name and a matching mass while its supporting chromatogram is headed with a different lot number. Keep the mismatch visible, request the correct report from the issuer and retain the correspondence that connects the replacement file to the certificate. A handwritten change to the local filename would conceal the original discrepancy. Ask the technical reviewer whether the unresolved item affects identity, purity or both before deciding whether the order can be accepted.

HYTAN · Biotin-labeled peptide service specification guide

Worked example

If an attachment uses an internal laboratory project number, ask the supplier for a cross-reference to the labelled lot named on its certificate. Record which issuer supplied that link and the file revision. A similar product name printed on the two documents leaves room for ambiguity.

Prepare your inquiry

Match the lot first, then match each analytical field to the question it answers.

Select the items you want to ask about.

Certificates of analysis

If a modified peptide is supplied as lyophilized powder, use the full modification description and lot number when checking its COA. A shared base name can refer to several variants.

Read a COA