Separate isotopic enrichment, chemical purity and assigned amount when buying labeled research reference materials.

Which properties does the grade actually describe?

Ask the laboratory to list the isotope designations, heavy material identifier, stated enrichment, chemical purity and amount basis separately. A percentage next to enrichment answers a different question from a percentage next to chromatographic purity. Thermo Fisher’s reference service lists these as separate product characteristics and offers different approaches to amount assignment. Its published service specifications describe that provider’s offerings and provide vocabulary for comparing quotations.

Thermo Fisher Scientific · Stable isotope peptide service specifications

A liquid chromatography instrument and a separate mass spectrometer share a laboratory work area.
Chromatography and mass spectrometry instrumentationThe reference instrument photograph gives context for the identity report requested from the actual testing laboratory.
Image creditsSarka Na kopci · Image source · CC BY-SA 4.0 · Converted to WebP.
A workbench holds sample racks, capped vials and preparation equipment.
Laboratory sample stationSeparate racks illustrate why the receiving list needs a unique identifier for each group of containers.
Image creditsGold Standard Analytics LLC · Image source · CC BY-SA 4.0 · Converted to WebP.

Should the light and heavy versions arrive together?

A project requesting both versions should identify each material on the order, the packing list and the rack map. Confirm whether each vial holds a single material, whether the versions arrive together and whether each has its own analytical record. Reserve a field for the unit in which the amount is assigned. This prevents a receiving team from treating a stated total shipment weight as an amount per vial.

Bachem · Net peptide weight and batch analytical data

Which substitution changes the buyer’s decision?

Suppose a supplier proposes a dry reference in place of a solution with an assigned concentration. The heavy material might have the same chemical description while the replacement changes what the buyer can document at receipt. Check that the person responsible for quantitation approves the new amount basis and that both versions remain identifiable on the order. If a reference certificate is supplied, verify which lot and form it covers before reusing it in the laboratory’s record.

Thermo Fisher Scientific · Stable isotope peptide service specifications

Worked example

If a laboratory wants an isotope-labelled material with a specific documentary grade, enter the grade designation exactly as issued and ask for a sample certificate. Have the buyer’s quality reviewer identify which fields are required before approving an offer described only as a comparable grade.

Prepare your inquiry

Write separate acceptance fields for isotope identity, enrichment, chemical purity and amount.

Select the items you want to ask about.

Certificates of analysis

If a modified peptide is supplied as lyophilized powder, use the full modification description and lot number when checking its COA. A shared base name can refer to several variants.